The main mechanism of UF membrane is to provide a reliable retention of suspended solids and microorganisms, making it ideal for drinking water applications, wastewater recycling and as an excellent pre-treatment to reverse osmosis (RO) systems.
The key know-how is the membrane itself. EuroTec develops high-strength, high-porosity and chemically-resistant PVDF hollow fibre membranes with a small and narrow pore-size distribution, resulting in consistently superior filtrate quality and excellent permeability with low transmembrane pressure (TMP).
The EuroTec ultrafiltration membranes are engineered to provide cost effective solutions with high operating reliability and superior filtrate quality through years of research and actual implementation in various water applications that undergo challenging circumstances has proven its viability and resilience in quality performance.
Specifications | Unit | ETUF-9060F | ETUF-9060R | ETUF-9040R | ETUF-9076D |
Membrane Material | - | PVDF | PVDF | PVDF | PVDF |
Membrane Area | m2 | 60 | 60 | 40 | 76 |
Pore Size | µm | 0.025 | 0.025 | 0.025 | 0.025 |
Filtration Mode | - | Outside-In | Outside-In | Outside-In | Outside-In |
Bacteria Removal | % | 99.9999 | 99.9999 | 99.9999 | 99.9999 |
Nominal Diameter | mm | 258 | 344 | 344 | 225 (Nominal) |
Nominal Length | mm | 2,130 | 2,340 | 1,600 | 2,360 |
Feed Connection (Size/ Type) | inch | 1.5 FNPT | 1.5 FNPT | 1.5 FNPT | DN50 |
Concentrate Connection (Size/ Type) | inch | 1.0 FNPT | 1.5 FNPT | 1.5 FNPT | DN50 |
Filtrate Connection (Size/ Type) | inch | 1.5 FNPT | 1.5 FNPT | 1.5 FNPT | DN50 |
Max Feed Pressure | bar | 2 | 2 | 2 | 6 |
Temperature Tolerance | °C | 5 – 40 | 5 – 40 | 5 – 40 | 5 – 40 |
pH Tolerance (Operation) | - | 1 – 12 | 1 – 12 | 1 – 12 | 1 – 12 |